Heart-Type Fatty Acid-Binding Protein (H-FABP)

PDB ID: 1HMT. Source: RCSB Protein Data Bank. For illustration purposes only.

VeriGoldTM H-FABP

The VeriGoldTM H-FABP Rapid Test is an immunochromatographic assay for the qualitative or quantitative determination of heart-type fatty acid-binding protein in whole blood, serum, or plasma. H-FABP is an early cardiac biomarker that may increase within 1–3 hours after symptom onset in acute myocardial infarction (AMI), earlier than traditional markers such as troponin. Depending on the format, the test provides either a qualitative result indicating the presence or absence of elevated H-FABP above a defined cutoff, or a quantitative value reflecting its concentration in the sample.

The test may assist in the evaluation of patients with suspected acute myocardial infarction and support clinical assessment in individuals presenting with acute chest pain. Quantitative results can further support interpretation of myocardial injury and may be useful in observing changes over time, including suspected reinfarction due to the rapid clearance of H-FABP from circulation. In both formats, results should be interpreted together with clinical findings and other laboratory or diagnostic data in emergency and urgent care settings.

Ref. Code 808039-1: Quantitative
808039: Qualitative
Analyte Heart-type fatty acid-binding protein (H-FABP)
Format POCT rapid test (cassette / cartridge)
Diagnostic Readout 808039-1: Quantitative
808039: Qualitative
Reading Time 15 minutes
Measuring Range 808039-1 (Quantitative): 2.5-100 μg/L
808039 (Qualitative): Not applicable
Cut-off Value 7 μg/L
Sensitivity / Specificity / r-Value 100% / 98.3% / 0.920
Storage Conditions 808039-1 (Quantitative): 2-8℃
808039 (Qualitative): 2-25℃
Shelf Life 808039-1 (Quantitative): 12 months
808039 (Qualitative): 16 months
Certificate CE, NMPA
Sample Types Whole blood, serum or plasma
Sample Volume Plasma or serum: 100 µL
Whole blood: 120 µL
Collection Method Venous blood
Sample Stability Stable for testing within 1 hour at room temperature (as validated)
Acceptable Anticoagulants EDTA / Heparin / Citrate (as applicable)
Notes on Handling Specimens should be collected and handled using standard laboratory procedures. Use fresh samples when possible and avoid hemolyzed, lipemic, or contaminated specimens.
Detection Method Immunochromatography
Antibody Format Monoclonal / sandwich
Signal Generation Colloidal gold
Reading Method Instrument-based
Mechanism The assay is based on a sandwich immunochromatographic principle, in which heart-type fatty acid-binding protein (H-FABP) in the sample binds to specific labeled antibodies during lateral flow migration along the membrane. The resulting antigen–antibody complexes are captured by immobilized antibodies at the test line, generating a detectable signal. Depending on the assay format, the signal is either interpreted qualitatively against a defined cutoff or measured quantitatively as proportional to the H-FABP concentration in the specimen.
Tests per Kit 20 Tests
Dimension of Kit Box 16.5 × 13.5 × 8cm
Boxes per Carton 55 Kits
Tests per Carton (Bulk) 1100 Tests
G.W. per Carton (Boxed) 20 kg
G.W. per Carton (Bulk) 23.6 kg
Carton Dimension 67 × 57.5 × 39 cm
Carton Volume 0.15 CBM
Packaging Format Individual sealed test kits / bulk configuration (as applicable)
Items Included - 20 test cassettes
- Instructions for Use
Storage & Shipping Conditions Standard ambient transport; store according to product label requirements