VeriGoldTM Adenovirus

The VeriGoldTM Adenovirus Rapid Test is a qualitative in vitro immunochromatographic assay for the rapid detection of adenovirus antigens in human fecal samples. The test is intended to support the detection of adenovirus infection in individuals with acute gastroenteritis. Adenovirus is a common cause of gastroenteritis in children, although it can also affect adults, particularly immunocompromised individuals.

As a non-invasive qualitative test, results are reported simply as positive or negative, enabling rapid bedside or laboratory decision-making without specialized equipment. Results are available within minutes from a fecal sample. This test is useful for supporting the differentiation of adenoviral gastroenteritis from bacterial or other viral causes, aiding appropriate patient management and timely infection control measures in pediatric wards, emergency departments, and outpatient clinics.

Ref. Code 808126-1
Analyte Human adenovirus antigen
Format POCT rapid test (cassette / cartridge)
Diagnostic Readout Qualitative
Reading Time 15–20 minutes
Measuring Range Not applicable
Cut-off Value Not applicable
Sensitivity / Specificity 93.71% / 99.18%
Storage Conditions 2–25°C
Shelf Life 18 months
Certificate CE
Sample Types Human fecal sample
Sample Volume Please refer to Collection Method
Collection Method - Collect stool using the sampling stick from three different sites of the specimen and place into the extraction buffer (1.5 mL).
- Mix thoroughly.
- Add 3 drops (~100 µL) of the extracted sample to the test device.
Sample Stability Stable for testing within 1 hour at room temperature (as validated)
Acceptable Anticoagulants EDTA / Heparin / Citrate (as applicable)
Notes on Handling Specimens should be collected and handled using standard laboratory procedures. Use fresh samples when possible and avoid hemolyzed, lipemic, or contaminated specimens.
Detection Method Immunochromatography
Antibody Format Monoclonal / sandwich
Signal Generation Colloidal gold
Reading Method Visual
Mechanism The assay is based on an immunochromatographic lateral flow principle, in which adenovirus antigens present in the fecal sample bind to specific labeled antibodies during migration along the membrane by capillary action. The resulting antigen–antibody complexes are captured by immobilized antibodies at the test line, producing a visible signal indicating the presence of adenovirus antigen in the specimen.
Tests per Kit 20 Tests
Dimension of Kit Box 16.5 × 13.5 × 8cm
Boxes per Carton 55 Kits
Tests per Carton (Bulk) 1100 Tests
G.W. per Carton (Boxed) 22.3 kg
G.W. per Carton (Bulk) 25.6 kg
Carton Dimension 67 × 57.5 × 39 cm
Carton Volume 0.15 CBM
Packaging Format Individual sealed test kits / bulk configuration (as applicable)
Items Included - 20 test cassettes
- 20 patient sets:
  - Collection tube pre-filled with buffer (1.5 mL per vial)
  - Stool collection paper
  - Sample collection instruction manual
- Instructions for Use
Storage & Shipping Conditions Standard ambient transport; store according to product label requirements