Cardiac Troponin, B-Type Natriuretic Peptide, D-dimer (3 in 1)

PDB ID: 1J1E, 1YK1, 2Q9I. Source: RCSB Protein Data Bank. For illustration purposes only.

VeriLumenTM cTnI+BNP+D-Dimer

The VeriLumenTM Cardiac Troponin I, B-Type Natriuretic Peptide & D-Dimer Rapid Test is a fluorescence immunochromatographic assay for the quantitative detection of cardiac troponin I (cTnI), B-type natriuretic peptide (BNP), and D-dimer in human whole blood or plasma samples. These biomarkers are associated with different cardiovascular and thrombotic conditions, allowing simultaneous assessment of myocardial injury, cardiac dysfunction, and coagulation activity. The assay provides rapid quantitative results to support timely clinical evaluation in laboratory and point-of-care settings.

cTnI is primarily used in the clinical assessment and auxiliary diagnosis of myocardial infarction, while BNP is commonly used in the evaluation of heart failure and cardiac stress. D-dimer is widely used in the assessment of coagulation and thrombotic disorders, including disseminated intravascular coagulation (DIC), thrombolytic therapy monitoring, and evaluation of suspected venous thromboembolic conditions. Combined quantitative measurement of these three biomarkers supports comprehensive cardiovascular assessment when interpreted together with clinical findings and other diagnostic information.

Ref. Code 808171
Analyte Cardiac Troponin I (cTnI), B-Type Natriuretic Peptide (BNP), D-dimer
Format Fluorescence lateral flow immunoassay (cassette format)
Diagnostic Readout Quantitative
Time to Result 15 minutes
Measuring Range cTnI: 0.05–30 ng/mL
BNP: 5–5000 pg/mL
D-Dimer: 0.05–10 mg/L
Reference Value cTnI: < 0.3 ng/mL
BNP: < 100 pg/mL
D-Dimer: < 0.5 mg/L
R2 ≥ 0.95
Storage Conditions 2–30°C
Shelf Life 18 months
Certificate CE, NMPA
Sample Types Human whole blood, plasma or serum
Sample Volume 100μL
Collection Method Capillary (fingerstick) or venous blood
Sample Stability Stable for testing within 1 hour at room temperature (as validated)
Acceptable Anticoagulants EDTA / Heparin / Citrate (as applicable)
Notes on Handling Specimens should be collected and handled using standard laboratory procedures. Use fresh samples when possible and avoid hemolyzed, lipemic, or contaminated specimens.
Detection Method Quantitative fluorescence immunochromatography
Antibody Format Multiplex / sandwich
Signal Generation Fluorescence signal (fluorescent-labeled immunochromatography)
Reading Method Instrument-based
Mechanism The assay is based on a multiplex fluorescence immunochromatographic sandwich principle, in which cardiac troponin I (cTnI), B-type natriuretic peptide (BNP), and D-dimer present in the sample bind to their respective specific fluorescently labeled antibodies during capillary migration along the membrane. The resulting antigen–antibody complexes are captured at separate immobilized test regions, and the fluorescence signals are measured independently and correlated with the concentrations of cTnI, BNP, and D-dimer in the specimen.
Tests per Kit 10/25/50 Tests
Dimension of Kit Box 21 × 13.5 × 8 cm
Kits per Carton 48 Kits
Tests per Carton (Bulk) 1200 Tests
G.W. per Carton (Boxed) 23.2 kg
G.W. per Carton (Bulk) 26.2 kg
Carton Dimension 67 × 57.5 × 39 cm
Carton Volume 0.15 CBM
Packaging Format Individual sealed test kits / bulk configuration (as applicable)
Items Included - Test cassette
- Desiccant
- Sample diluent
- ID chip
- Instructions for Use
Storage & Shipping Conditions Standard ambient transport; store according to product label requirements