The VeriGoldTM Rotavirus & Adenovirus Rapid Test is a qualitative in-vitro immunochromatographic assay for the rapid detection of rotavirus and adenovirus antigens in human fecal samples. Rotavirus and adenovirus are common causes of acute gastroenteritis, particularly in infants and young children. This test is intended to support the detection of rotavirus and adenovirus infections in individuals with suspected acute gastroenteritis.

As a qualitative test, results are reported as positive or negative, allowing rapid decision-making at the point of care or in the laboratory without the need for specialized equipment. With results available in 15–20 minutes from a fecal sample, the Rotavirus & Adenovirus Rapid Test supports timely clinical assessment and patient management in pediatric wards, emergency departments, and outpatient clinics.

Ref. Code 808128-1
Analyte Rotavirus and adenovirus antigens
Format POCT rapid test (cassette / cartridge)
Diagnostic Readout Qualitative
Reading Time 15-20 minutes
Measuring Range Not applicable
Cut-off Value Not applicable
Sensitivity / Specificity Rotavirus: 93.62% / 96.65%
Adenovirus: 93.71% / 99.18%
Storage Conditions 2–25°C
Shelf Life 18 months
Certificate CE
Sample Types Human fecal sample
Sample Volume Please refer to Collection Method
Collection Method - Collect stool using the sampling stick from three different sites of the specimen and place into the extraction buffer (1.5 mL).
- Mix thoroughly.
- Add 3 drops (~100 µL) of the extracted sample to the test device.
Sample Stability Stable for testing within 1 hour at room temperature (as validated)
Acceptable Anticoagulants EDTA / Heparin / Citrate (as applicable)
Notes on Handling Specimens should be collected and handled using standard laboratory procedures. Use fresh samples when possible and avoid hemolyzed, lipemic, or contaminated specimens.
Detection Method Immunochromatography
Antibody Format Multiplex / sandwich
Signal Generation Colloidal gold
Reading Method Visual
Mechanism The assay is based on a dual immunochromatographic lateral flow principle, in which rotavirus and adenovirus antigens present in the fecal sample bind to their respective specific labeled antibodies during migration along the membrane by capillary action. The resulting antigen–antibody complexes are captured at separate test regions by immobilized antibodies specific to each virus, producing visible signals indicating the presence of rotavirus and/or adenovirus antigens in the specimen.
Tests per Kit 20 Tests
Dimension of Kit Box 16.5 × 13.5 × 8cm
Boxes per Carton 55 Kits
Tests per Carton (Bulk) 1100 Tests
G.W. per Carton (Boxed) 22.3 kg
G.W. per Carton (Bulk) 25.6 kg
Carton Dimension 67 × 57.5 × 39 cm
Carton Volume 0.15 CBM
Packaging Format Individual sealed test kits / bulk configuration (as applicable)
Items Included - 20 test cassettes
- 20 patient sets:
  - Collection tube pre-filled with buffer (1.5 mL per vial)
  - Stool collection paper
  - Sample collection instruction manual
- Instructions for Use
Storage & Shipping Conditions Standard ambient transport; store according to product label requirements