Myoglobin (Myo)

PDB ID: 3RGK. Source: RCSB Protein Data Bank. For illustration purposes only.

VeriLumenTM 肌红蛋白

The VeriLumenTM Myo Rapid Test is a fluorescence immunochromatographic assay for the quantitative detection of myoglobin (Myo) in human whole blood, plasma, or serum samples. Myoglobin is an early-release biomarker of muscle injury that may increase rapidly following myocardial damage, making it useful in the early clinical evaluation of suspected acute myocardial infarction (AMI). The assay provides rapid quantitative results to support timely assessment in laboratory and point-of-care settings.

This test is mainly used as an aid in the clinical assessment and auxiliary diagnosis of myocardial infarction, supporting healthcare professionals in evaluating patients presenting with chest pain and other symptoms associated with acute coronary syndromes. Quantitative Myo measurement may also assist in the early detection and monitoring of myocardial injury when interpreted together with clinical findings and other diagnostic information.

Ref. Code 808168
Analyte Myoglobin (Myo)
Format Fluorescence lateral flow immunoassay (cassette format)
Diagnostic Readout Quantitative
Time to Result 10 minutes
Detection Range 3–400 ng/mL
Reference Value 58 ng/mL
R2 ≥ 0.95
Storage Conditions 2–30°C
Shelf Life 18 months
Certificate CE
Sample Types Human whole blood, plasma or serum
Sample Volume 100μL
Collection Method Venous blood
Sample Stability Stable for testing within 1 hour at room temperature (as validated)
Acceptable Anticoagulants EDTA / Heparin / Citrate (as applicable)
Notes on Handling Specimens should be collected and handled using standard laboratory procedures. Use fresh samples when possible and avoid hemolyzed, lipemic, or contaminated specimens.
Detection Method Quantitative fluorescence immunochromatography
Antibody Format Monoclonal / sandwich
Signal Generation Fluorescence signal (fluorescent-labeled immunochromatography)
Reading Method Instrument-based
Mechanism The assay is based on a fluorescence immunochromatographic sandwich principle, in which myoglobin (Myo) present in the sample binds to specific fluorescently labeled anti-MYO antibodies during capillary migration along the membrane. The resulting antigen–antibody complexes are captured by immobilized antibodies at the test region, and the fluorescence signal is measured and correlated with the Myo concentration in the specimen.
Tests per Kit 10/25/50 Tests
Dimension of Kit Box 21 × 13.5 × 8 cm
Kits per Carton 48 Kits
Tests per Carton (Bulk) 1200 Tests
G.W. per Carton (Boxed) 23.2 kg
G.W. per Carton (Bulk) 26.2 kg
Carton Dimension 67 × 57.5 × 39 cm
Carton Volume 0.15 CBM
Packaging Format Individual sealed test kits / bulk configuration (as applicable)
Items Included - Test cassette
- Desiccant
- Sample diluent
- ID chip
- Instructions for Use
Storage & Shipping Conditions Standard ambient transport; store according to product label requirements