Cardiac Troponin I (cTnI)

PDB ID: 1J1E. Source: RCSB Protein Data Bank. For illustration purposes only.

VeriLumenTM 心肌肌钙蛋白I

The VeriLumenTM cTnI Rapid Test is a fluorescence immunochromatographic assay intended for the quantitative measurement of cardiac troponin I (cTnI) concentration in human whole blood, plasma, or serum. Cardiac troponin I is a highly specific biomarker of myocardial injury and is widely used in the clinical assessment of patients with suspected acute myocardial infarction (AMI). The assay provides rapid and sensitive quantitative results to support timely evaluation in laboratory and point-of-care settings.

This test is mainly used as an aid in the clinical assessment and auxiliary diagnosis of myocardial infarction, supporting healthcare professionals in evaluating patients presenting with chest pain and other symptoms suggestive of acute coronary syndromes. Quantitative cTnI measurement may also assist in monitoring cardiac injury progression when interpreted together with clinical findings and other diagnostic information.

Ref. Code 808164
Analyte Cardiac Troponin I (cTnI)
Format Fluorescence lateral flow immunoassay (cassette format)
Diagnostic Readout Quantitative
Time to Result 10 minutes
Measuring Range 0.05–30 ng/mL
Reference Value 0.3 ng/mL
R2 ≥ 0.95
Storage Conditions 2–30°C
Shelf Life 18 months
Certificate CE, NMPA
Sample Types Human whole blood, plasma or serum
Sample Volume 100μL
Collection Method Venous blood
Sample Stability Stable for testing within 1 hour at room temperature (as validated)
Acceptable Anticoagulants EDTA / Heparin / Citrate (as applicable)
Notes on Handling Specimens should be collected and handled using standard laboratory procedures. Use fresh samples when possible and avoid hemolyzed, lipemic, or contaminated specimens.
Detection Method Quantitative fluorescence immunochromatography
Antibody Format Monoclonal / sandwich
Signal Generation Fluorescence signal (fluorescent-labeled immunochromatography)
Reading Method Instrument-based
Mechanism The assay is based on a fluorescence immunochromatographic sandwich principle, in which cardiac troponin I (cTnI) present in the sample binds to specific fluorescently labeled anti-cTnI antibodies during capillary migration along the membrane. The resulting antigen–antibody complexes are captured by immobilized antibodies at the test region, and the fluorescence signal is measured and correlated with the cTnI concentration in the specimen.
Tests per Kit 10/25/50 Tests
Dimension of Kit Box 21 × 13.5 × 8 cm
Kits per Carton 48 Kits
Tests per Carton (Bulk) 1200 Tests
G.W. per Carton (Boxed) 23.2 kg
G.W. per Carton (Bulk) 26.2 kg
Carton Dimension 67 × 57.5 × 39 cm
Carton Volume 0.15 CBM
Packaging Format Individual sealed test kits / bulk configuration (as applicable)
Items Included - Test cassette
- Desiccant
- Sample diluent
- ID chip
- Instructions for Use
Storage & Shipping Conditions Standard ambient transport; store according to product label requirements